Lab Companion™ KMV-100 Test Chamber 1000L (-35 to 180c), H-Flow, 380v

Product no.: AAHK9050K

"Our 42nd Year of Competitive Pricing"

$44,744.00
Price plus sales tax, plus delivery
Delivery weight: 970 lb

Lab_Companion_LOGO_8-22-22

 

KMV-100 Test Chamber 1000L, Temp range: (-35 to 180c), Floor model, Horizontal flow, 380v

 

 Testing for electric and electronic components, and sensors.

 Testing for semiconductors, PCB, LCD, and LED.

 Pharmaceutical tests.

 Mechanical / Military / Aircraft engineering.

 Automobile, Transport/automobile supply industries.

 Chemical / Petrochemical industries.

 Construction materials / Plastic / Rubber / Textile industries.

 Testing mold, liquor, cigar, paintings, and compounds.

 Testing metal-related industries like plating etc.

 

 

Specifications

Model (KMV) KMV-012 KMV-025 KMV-040 KMV-070 KMV-100

Chamber volume (L / cu ft)

125 / 4.4

253 / 8.9

420 / 14.8

720 / 25.4

1000 / 35.3

Controller

Programmable, Touch screen-type controller (3.5” color monitor)

Temperature range (℃ / ℉)

-35 to 180 / -31 to 356

Temp fluctuation 1) 2) 

(±℃ / ±℉)

at -35℃

0.5 / 0.9

0.5 / 0.9

0.3 / 0.54

0.2 / 0.36

 0.3 / 0.54

at -25℃

0.3 / 0.54

0.3 / 0.54

0.3 / 0.54

0.2 / 0.36

0.2 / 0.36

at -10℃

 0.3 / 0.54

 0.3 / 0.54

0.2 / 0.36

 0.3 / 0.54

 0.3 / 0.54

at 25℃

0.2 / 0.36

0.2 / 0.36

0.5 / 0.9

0.4 / 0.72

0.2 / 0.36

at 70℃

0.3 / 0.54

0.3 / 0.54

0.4 / 0.72

0.3 / 0.54

0.2 / 0.36

at 100℃

0.3 / 0.54

0.3 / 0.54

0.3 / 0.54

0.3 / 0.54

0.3 / 0.54

at 150℃

0.2 / 0.36

0.2 / 0.36

0.3 / 0.54

0.2 / 0.36

0.2 / 0.36

at 180℃

0.4 / 0.72

0.4 / 0.72

0.3 / 0.54

0.3 / 0.54

0.2 / 0.36

Heating time 2) (min.) from 25℃ to 180℃

64

64

55

100

76

Cooling time 2) (min.) from 25℃ to -35℃

41

41

37

38

44

Recovery time 2)

after door was opened for 30 sec. (min.)

at -35℃

8.0

8.0

6.5

7.0

6.0

at -25℃

3.5

3.5

7.5

6.0

7.0

at -10℃

2.5

2.5

6.5

6.5

6.5

at 25℃

4.0

4.0

5.5

4.5

5.0

at 70℃

4.0

4.0

5.5

5.0

8.0

at 100℃

4.0

4.0

6.5

6.0

6.0

at 150℃

4.0

4.0

4.5

4.3

3.5

at 180℃

11.5

11.5

6.0

5.0

4.0

No. of wire shelves (standard / max.)

2 / 13

2 / 18

2 / 23

2 / 30

2 / 33

Distance between shelves

30mm / 1.2"

Max. load per shelf (kg / lbs)

15 / 33.1

20 / 44.1

30 / 66.1

40 / 88.2

45 / 99.2

Permitted total load (kg / lbs)

50 / 110.2

70 / 154.3

90 / 198.4

120 / 264.6

150 / 330.7

Dimension (W×D×H)

Interior

(mm / inch)

500×500×500/ 19.7×19.7×19.7

600×650×650/ 23.6×25.6×25.6

750×700×800/ 29.5×27.6×31.5

900×800×1000/ 35.4×31.5×39.4

1000×910×1100/ 39.4×35.8×43.3

Exterior

(mm / inch)

1070×775×1385/ 42.1×30.5×54.5

1170×925×1585/ 46.1×36.4×62.4

1370×975×1780/ 53.9×38.4×70.1

1495×1625×1650/ 58.9×63.9×64.9

1595×1725×1800/ 62.8×67.9×70.9

Net weight

(kg / lbs)

170 / 374.8

260 / 573.2

320 / 705.5

390 / 859.8

440 / 970

Interface port

Basically RS-232C [RS-485(maximum 32 units control)-optional]

Electrical requirements (230V, 60Hz) 1ph / 19.2A 1ph / 26A      
Cat. No. AAHK9011K AAHK9021K - - -
Electrical requirements (230V, 50Hz) 1ph / 19.2A 1ph / 26A      
Cat. No. AAHK9012K AAHK9022K - - -
Electrical requirements (380V, 50-60Hz)      3ph / 12.5A 3ph / 18A 3ph / 19.4A
Cat. No. - - AAHK9030K AAHK9040K AAHK9050K

1) According to IEC 60068-3-5. 2) According to DIN 12880.  Above specification value is recorded by 230v/50Hz, 380/50Hz. ※ Above specifications can be changed without prior notice.

 

 

Performance

  • Suitable for a specific use such as heat treatment and drying process.
  • Microprocessor PID control / Temperature calibration / Automatic tuning.
  • Air-tight door closure with double-sealed packing.
    - Heat-resistant silicone double packing completely blocks high heat leakage from the inner chamber.
    - Two-point door latch also enhances tightness to door closure.
  • Energy efficiency is achieved thanks to the optimization of the insulation system.
    - Even if the unit is operating at max. temperature, the surface of the unit doesn’t allow high temperatures of over 51℃. (DIN EN 563).
  • Reliable design and production of the door are guaranteed.
    - Evaluates the results after opening the door by 90 degrees and applying a 50kg load to the point of 30cm from the hinges.

 

Convenience

  • Corrosion resistance stainless steel inner chamber.
  • Space efficient and easy loading chamber design.
    - Included two shelves for loading large amounts of samples.
    - Heavy load shelving, rated for 40kg are also available (option).
  • User-friendly LCD controller.
      - Colorful interactive touch-type LCD controller.
    - Set point temperature and present temperature are clearly shown together on display.
    - Sufficient programmable control support.
    - Operating progress can be shown in graph mode for better data understanding.
    - Automatic start/stop can be programmed for unattended operations.
    - Display indicates abnormal temperature changes or power failures.
    - Selective bilingual language support.
    (Korean / English or English / Chinese, selectable only when placing an order)
    - Temperature and other operating parameters can be recorded using a six-channel digital recorder. (option).
  • Computer interface.
    - RS-485 communication port enables connection up to a maximum of 32 units. Simultaneous monitoring and operating of multiple units is an available feature (option).
    - Program patterns are simple to set with the use of our software.
    - Easy to check the status of real-time operations. Graph data supports easy understanding.
    - Storage and documentation of programs.
    - Data with saving capabilities in excel and text format.
    - Storage of program information, backup of value settings, recovery, and temperature values.
    - RS-232 communication port as a standard offer.

Safety

  • User selectable operation mode after power interruption
    - Either Automatic run or Manual run.
  • Over-temperature protection.
  • Over-current and current leakage protection.
    (ELCB, earth leakage circuit breaker)
  • Independent safety circuit breaker.
    - Important parts such as the controller and heaters are highly secured from short circuits. Especially each heater has an individual circuit breaker to completely break a short circuit.
  • Reversed-phase protection.
    - Electrical connection error indicator helps the user to rapidly fix the connection.
  • Over-current protection of the motor. Automatic shut-off in situations where there is an over-current to the motor.
  • Open door warning.
    - Heater and fan stop when the door is in the open state.
  • Electric wiring panel access warning.
    - Automatic stop if the cover of the electric wiring panel is opened.
  • Built-in door lock with a key

 

Description No
Programmable pattern capacity 100
Pattern repeat time 999
Part repeat time 255
Max. segments per a pattern 100
Available max. segments* 2000
Programmable process time per a segment 0 to 99 hr. 59 min.

* Even though the max. segments per pattern are 100, the total available segments are up to 6000, not 10000, therefore the arrangement of the number of segments and patterns will need to be done properly.

 

 

Heating & Cooling Test Chambers (Floor Models)

Model KBD KMV JMV
Air flow Horizontal airflow Horizontal airflow Vertical airflow
Chamber volume (L) 125, 253, 420 125, 253, 420,720, 1000 125, 253, 420,720, 990
Temp. control Operating temp. range (℃/℉) -70 to 180 / -94 to 356 -35 to 180 / -31 to 356 -35 to 180 / -31 to 356
Fluctuation at 100℃ (±℃/℉) 0.2 / 0.36 0.4, 0.3, 0.2/ 0.72, 0.54, 0.36 0.5, 0.3, 0.4/ 0.9, 0.54, 0.72
Variation at 100℃ (±℃/℉) 1.2, 1.0 / 2.16, 1.8 1.0, 0.9  / 1.8, 1.62 1.0, 0.8, 1.2, 0.9/ 1.8, 1.44, 2.16, 1.62
Control Timer Wait on/off Wait on/off Wait on/off
Auto-tuning X X X
Program function X X X
Computer interface RS-232 port,
RS-485 port (optional)
RS-232 port,
RS-485 port (optional)
RS-232 port,
RS-485 port (optional)
Safety Over temp. limit X X X
Door open alarm X X X
Over-current limit X X X
Auto-run (power failure) X X X

 

 

Optional Accessories

Cat. No. Description Model
KMV
AAA8T505

Recorder (digital, 6 channels)

X
AAA8T540

Interface converter (RS - 485 → 232) included a cable (5m / 16.4ft)

X
AAA80550

Warning signal lamp

X
LTV0070

Wire shelf for LBV/LTV/KBD/KMV/JMV/PBV/PMV-012 (462x470mm / 18.2x18.5”)

X
LTV0053

Wire shelf for LBV/LTV/KBD/KMV/JMV/PBV/PMV-025 (562x620mm / 22.1x22.4”)

X
LTV0029

Wire shelf for LBV/LTV/KBD/KMV/JMV/PBV/PMV-040 (712x670mm / (28.0x26.4”)

X
LTV0030

Wire shelf for LBV/LTV/KBD/KMV/JMV/PBV/PMV-070 (862x770mm / 33.9x30.3”)

X
LTV0057

Wire shelf for LBV/LTV/KBD/KMV/JMV/PBV/PMV-100 (962x880 / 37.9x34.6”)

X
AAAK1501

Perforated shelf for LBV/LTV/KBD/KMV/JMV/PBV/PMV-012 (462x470mm / 18.2x18.5”) (max. load 40kg)

X
AAAK1502

Perforated shelf for LBV/LTV/KBD/KMV/JMV/PBV/PMV-025(562x620mm / 22.1x22.4”) (max. load 40kg)

X
AAAK1503

Perforated shelf for LBV/LTV/KBD/KMV/JMV/PBV/PMV-040 (712x670mm / (28.0x26.4”) (max. load 40kg)

X
AAAK1504

Perforated shelf for LBV/LTV/KBD/KMV/JMV/PBV/PMV-070 (862x770mm / 33.9x30.3”) (max. load 40kg)

X
AAAK1505

Perforated shelf for LBV/LTV/KBD/KMV/JMV/PBV/PMV-100 (962x880 / 37.9x34.6”) (max. load 40kg)

X
AAAK8512 Cable port (Φ80) X
AAAK8511 Cable port (Φ50) X
AAA80691 Gas purge system X

We also recommend

* Prices plus sales tax, plus delivery

Browse these categories as well: Heating & Cooling Test Chambers (Floor) KBD-KMV-JMV-PBV-PMV, Catalog