Lab Companion TH-ICH-800 Pharmaceutical Stability Test Chamber 760L, 230v

Product no.: AAHC1015K

"Our 43rd Year of Competitive Pricing"

Old price $43,472.00
$36,951.00
You save $6,521.00
Price plus sales tax, plus delivery
Delivery weight: 948 lb

Lab_Companion_LOGO_8-22-22

 

TH-ICH-800 Pharmaceutical Stability Test Chamber (760L), Floor Model, 230v 50-60Hz

 

Meets ICH Guidelines Q1A-Stability test (R2), Q1B-Photostability test (Option 2).

 

 

Specifications
Model TH-ICH-300 TH-ICH-800
Chamber volume (L / cu ft) 300 / 10.6 760 / 26.8
Controller PID control (LCD Type)
Temperature 1) Range without humidity (℃ / ℉) -5 to 85 / 23 to 185
without Light 0 to 85 / 32 to 185 with Light
with humidity (℃ / ℉) +15 to 85 / 59 to 185 with Light
Fluctuation 1) (±℃ / ℉) at 40℃ / 60%RH 0.3 / 0.55 0.3 / 0.55
Variation 1) (±℃ / ℉) at 40℃ / 60%RH 0.5 / 0.9 0.7 / 1.3
Time Heating 25min (20℃ → 85℃) 30min (20℃ → 85℃)
Cooling 35min (20℃ → -5℃) 40min (20℃ → -5℃)
Humidity Range (%RH) 20 to 85
※ See page 231 for a more detailed humidity range check.
Fluctuation 2) (±%RH) at 60%RH / 40℃ 3
Variation 2) (±%RH) at 60%RH / 40℃ 5
Light source (ICH Q1B option 2) Cool white 3) 6,000 lux 6,500 lux
Ultraviolet-A 3) 4.5 W/㎡ 5 W/㎡
Light uniformity VIS. : ±10%UVA : ±15% VIS. : ±15%UVA : ±15%
Typical time required to reach ICH
Recommendation of 1.2 million lux-hr
≒ 200Hr ≒ 184Hr
Typical time required to reach ICH
recommendation of 200 W-hr/m2
≒ 50Hr ≒ 40Hr
Refrigeration System Air-cooled
Refrigerant R- 404A
Water tank Capacity (L / cu ft) 15 / 0.53
Water quality pH6.2 ~ 7.2, Electrical conductivity 20㎲ / cm to below
No. of wire shelves (standard / max.) 2 / 8 2 / 17
Distance of between shelves (mm / inch) 60 / 2.4 60 / 2.4
Max. load per shelf (kg / lbs) 25 / 55.1 40 / 88.2
Permitted total load (kg / lbs) 75 / 165.3 100 / 220.5
Dimension (W×D×H) Interior (mm / inch) 750×650×650 / 29.5×25.6×25.6 750×880×1160 / 29.5×34.6×45.7
Exterior (mm / inch) 1130×985×1520 / 44.5×38.8×59.8 1220×1215×1965 / 48×47.8×77.4
Net weight (kg / lbs) 280±10 / 617±22 400±10 / 882±22
Cable port Basically one hole provided / Ø 50mm (2”),
Optionally max. two holes available / Ø 50 or 80mm (2 or 3.2”)
Interface port Basically RS-232C, [RS-485 : optional]
Electrical requirements AC230V, 1ph, 60Hz 15.4 A 24.5 A
Cat.No. AAHC1001K AAHC1015K
AC230V, 1ph, 50Hz 14.7 A 23.5 A
Cat.No. AAHC1002K AAHC1015K
Warranty (Yrs)   2 2

1) All specifications are under ambient temperature 20℃ (68℉), with No load.
2) Technical data according to DIN 12880, and IEC 60068.
3) The value is measured on the center of the chamber
 at the point of vertical direction.

 

Stability test ICH guideline Q1A (R2)

  • Operating progress visible through graph mode for better data analysis.
  • Cyclic defrost system, designed to work excellently for the long period stability test operation. (※Temperature and humidity changes may occur during automatic defrost.)
  • Maintenance of the water supply is easily performed with a front water tank.
    - Water level check indicated by water level bar in the tank.
  • Water supply during operation is also available for long-term test purposes.
  • The direct water system provides users with great convenience when performing long-term tests. (optional)

Photostability test ICH guidelineQ1B (Option 2)

  • Built-in UV and fluorescent lamps for uniform luminescence.
  • Equipped with movable UV and VIS sensors.
  • Independent lamp controller
    - An indicator for the total usage time of UV and fluorescent lamps.
  • The convenient set function of cumulative dosage and lamp Of

Performance

  • Microprocessor PID control / Temperature calibration / Automatic tuning.
  • Rapid humidity control is achieved by adapting the humidification tank interior to the chamber.
  • Air-tight door closure with perfect sealed packing. Heat-resistant silicone packing completely blocks high heat leakage from the inner chamber.
  • Includes 2 wire shelves.

Convenience

  • Two different-sized models are available to suit any user’s needs.
  • Corrosion-resistant stainless steel chamber.
  • Cable port for introduction of external probes or wires.
    - 50mm diameter cable port comes standard on the left side of the unit.
    - Additional 50mm or 80mm diameter cable ports, custom ordered. (optional)
  • Inner glass door with entry ports for handling samples without affecting inner chamber temperature and humidity. (optional)
  • Casters for easy mobility during installation or relocation.
  • User-friendly LCD controller.
    - Colorful interactive touch-type LCD controller.
    - Set point temperature and present temperature are clearly shown together on display.
    - Sufficient programmable control support.
    - Operating progress can be shown in graph mode for better data understanding.
    - Automatic start/stop can be programmed for unattended operations.
    - Display indicates abnormal temperature changes or power failures.
    - Selective bilingual language support.
    (Korean / English or English / Chinese, selectable only when placing an order)
    - Temperature and other operating parameters can be recorded using a six-channel digital recorder.(optional)
  • Computer interface.
    - RS-485 communication port (optional) enables connection up to a maximum of 32 units. Simultaneous monitoring and operating of multiple units is an available feature.
    - Program patterns are simple to set with the use of our software.
    - Easy to check the status of real-time operations. Graph data supports easy understanding.
    - Storage and documentation of programs.
    - Data with saving capabilities in excel and text format.
    - Storage of program information, backup of value settings, recovery, and temperature values.
    - RS-232 communication port as a standard offer.

Safety

  • Built-in door lock with a key.
  • Automatic shut off after overheating alarm is actuated. 
  • Low and empty water level alarm.
  • Power supply leakage breaker.
  • Over current protection.
  • Open door alarm.

 

 

Description No.
Programmable pattern capacity 100
Pattern repeat time 999
Part repeat time 255
Max. segments per a pattern 100
Available max. segments* 2000
Programmable process time per a segment 0 to 99 hr. 59 min.

 

* Even though the max. segments per pattern are 100, the total available segments are up to 6000 not 10000, therefore arrangement of the number of segment and patterns will need to be done properly.

 

 

JT_TH-ICH_Stability_Chart

 
 
Accessory Check List
Description Models
TH-G   TH-I   TH-KH  TH-TG  TH-ICH  TH-CR 
Recorder (6 points)
Recorder (digital, 6 channels)
interface converter RS-485C → 232C included a cable (5m / 16.4ft)
Interface cable (5m / 16.4ft)
Warning signal lamp
Inner glass door -
Viewing window -
Wire shelf
Perforated shelf
Cable port (Ø 50mm / 2”)
Cable port (Ø 80mm / 3.2”)
Temperature sensor (RTD type)
Humidity sensor
Fluorescent lamp (Cool White) - - - - -
UVA lamp - - - - -
UV sensor - - - - -
Illumination Sensor - - - - -
HEPA filter - - - - -
ULPA filter - - - - -
Water cartridge tank (Water Container) -
Water purifier
Direct water system

  = Standard  = Optional, 1) 80mm cable access hole is NOT available for 25L chamber.

 

 

 

Optional Accessories
Cat. No. Description Suitable for
AAA8T500 Recorder (6 points) All models
AAA8T505 Recorder (digital, 6 channels) All models
AAA8T540 interface converter RS-485C →
232C included a cable (5m / 16.4ft)
All models
AAA8T542 Interface cable (5m / 16.4ft) All models
AAA80550 Warning signal lamp All models
AAA81552 Inner glass door TH-G/I/KH-180
AAA81551 TH-G/I/KH-300, 408, CR-270
AAA81550 TH-G-800, 1000
AAAC2501 TH-TG-180
AAAC2502 TH-TG-300, 408
AAAC2503 TH-TG-800, 1000
AAA81554 TH-ICH-300
AAA81555 TH-ICH-800
AAA8T610 Cable port (Ø 50mm / 2”) All models
AAA8T611 Cable port (Ø 80mm / 3.2”) All models
CFA1185 Temperature sensor (RTD type) All models
CFA7113 Humidity sensor All models
RTD1190 Fluorescent lamp (cool white) TH-ICH-300
RTD1191 TH-ICH-800
RTD1188 UVA lamp TH-ICH-300
RTD1189 TH-ICH-800
AAA80680 THE-680 UV sensor TH-ICH-300/800
AAA80681 THE-681 Illumination sensor TH-ICH-300/800
AAA80661 Door lock device TH-ICH-300/800
EDA9184 HEPA filter TH-CR-270
EDA9175 ULPA filter TH-CR-270
AAA80622 Water cartridge tank

All models

AAA8T621 Water purifier All models
AAA80620 Direct water system All models

 

 

 

Optional Accessories (Shelves)
Cat. No. Description Suitable for
EDA8212 Wire shelf TH-G/I/KH-180
EDA8213 TH-G/I/KH-300
EDA8214 TH-G/I/KH-408
EDA8215 TH-G-800
EDA8216 TH-G-1000
RTD1302 TH-TG-180
RTD1303 TH-TG-300
RTD1300 TH-TG-408
RTD1304 TH-TG-800
RTD1301 TH-TG-1000
RTD1305 TH-G/TG-1500
RTD1196 TH-ICH-300
RTD1198 TH-ICH-800
STT1040 TH-CR-270
AAA80602-1

   Perforated shelf    

 

 

TH-G/I/KH-180
AAA80602-2 TH-G/I/KH-300
AAA80602-3 TH-G/I/KH-408
AAA80602-4 TH-G-800
AAA80602-5 TH-G-1000
AAA80604-11 TH-TG-180
AAA80604-12 TH-TG-300
AAA80604-13 TH-TG-408
AAA80604-14 TH-TG-800
AAA80604-15 TH-TG-1000
AAA80604-16 TH-G/TG-1500
AAA80604-2 TH-ICH-300
AAA80604-4 TH-ICH-800
AAA80603-1 TH-CR-270

 

We also recommend

* Prices plus sales tax, plus delivery

Browse these categories as well: Catalog, Pharmaceutical Stability Test Chambers (Floor) TH-ICH