TC3-KE-100 Heating & Cooling Test Chamber (100L), Temp. range: (-35 to 150c), Tabletop, Vertical flow w/ IoT, 230v
Test for reliability, durability, climate, freezing, resistance, quality assurance, and thermal endurance.
Specifications & Ordering Information
Model (TC3-KE) |
TC3-KE-025 |
TC3-KE-065 |
TC3-KE-100 |
Temperature data |
Range (℃ / ℉) |
-35 to 150
/ -31 to 302 |
-35 to 150
/ -31 to 302 |
-35 to 150
/ -31 to 302 |
Fluctuation (±℃ / ℉) 1) |
0.3 / 0.54 |
0.3 / 0.54 |
0.3 / 0.54 |
Variation (±℃ / ℉) 2) |
0.5 / 0.9 |
0.5 / 0.9 |
0.5 / 0.9 |
Heating time 3) |
60 |
60 |
60 |
Cooling time 4) |
70 |
70 |
70 |
Interior dimensions |
Chamber volume (L / cu ft) |
25 / 0.88 |
65 / 2.3 |
100 / 3.53 |
Width (mm / inch) |
350 / 13.8 |
400 / 15.7 |
500 / 19.7 |
Depth (mm / inch) |
220 / 8.7 |
330 / 13 |
380 / 15 |
Height (mm / inch) |
350 / 13.8 |
495 / 19.5 |
530 / 20.9 |
Quantity of shelves (standard/max.) |
2/7 |
2/10 |
2/10 |
Distance of between shelves (mm / inch) |
20 / 0.8 |
20 / 0.8 |
20 / 0.8 |
Max. load per shelf (kg /lbs) |
25 / 55.1 |
25 / 55.1 |
25 / 55.1 |
Permitted total load (kg / lbs) |
65 / 143.3 |
65 / 143.3 |
65 / 143.3 |
Cable port (Ø, mm / inch) |
50 / 2 |
50 / 2 |
50 / 2 |
Weight (kg / lbs) |
110 / 242.5 |
140 / 308.6 |
150 / 330.7 |
Electrical
requirements |
AC230V, 1ph, 60Hz |
7.4A |
8.8A |
10.8A |
Cat. No. |
AAH861131K |
AAH861231K |
AAH861331K |
AC230V, 1ph, 50Hz |
7.4A |
8.8A |
10.8A |
Cat. No. |
AAH861132K |
AAH861232K |
AAH861332K |
Warranty (Yrs) |
|
2 |
2 |
2 |
※ The above specifications are tested according to DIN 12880 and IEC 60068 standards. ※ Permissible environmental conditions are 18 - 30°C (recommended 20°C), 85% RH or less, and under 2000m above sea level.
1) The set value is set under the conditions of 100°C.
2) The set value is set under the conditions of 25°C.
3) TC3-KE : -40℃ to 100℃(-40℉ to 212℉), TC3-ME : -20℃ to 100℃(-4℉ to 212℉)
4) TC3-KE : 20℃ to -40℃(68℉ to -40℉), TC3-ME : 20℃ to -20℃(68℉ to -4℉)
Temperature and Humidity Chamber, TH3 Series (IoT) Internet of Things
Optimized Model Configuration
- 2 series (KE, ME) according to temperature control range.
TC3-KE ; -35 ~ 150℃
TC3-ME ; -20 ~ 150℃
- Standard-type heating & cooling chambers for selecting the optimized model according to test conditions.
- Dedicated stand for convenient use and relocation (option).
- Recorder for maintaining test records (option).
Structural Functional Features
- Proven reproducibility and reliability with a structural design optimized for miniaturization.
- Compact design for excellent space saving.
- Excellent thermal insulation and sealing to ensure stable temperature and cooling reproducibility even for repeated test use.
- The door has a double-sealing structure and excellent air tightness.
Use Convenience Features
- (IoT) Internet of Things. Monitor via mobile app anytime, anywhere with LC Connected (mobile monitoring system) when purchasing the optional LC Green Box.
- Convenient operation with 5.6-inch color touch display controller.
- Easy observation of samples with tempered glass doors with built-in heating wire and LED lamp.
- By displaying the operation status of the device with LED colors, convenient to identify the chamber's status from afar.
- The cable port (ø 50 mm) included as standard makes it convenient to connect external equipment. Cable port (ø80 mm) available in models TC3-ME-065/100 (option).
- The door structure can be easily opened or closed.
- Door handle with built-in key lock.
- Identification of the control and operating conditions at the front of the product.
- The stainless steel internal chamber provides clean maintenance and excellent corrosion resistance.
- Easy to clean as it is easy to remove the refrigerator condenser grill, making it convenient to maintain the efficiency of refrigeration.
- Equipped with easy-to-move installed casters.
Multifunction Control System
- Highly-reliable control through calibration.
- Auto-tuning by subdivided PID zone for more precise control stability.
- RS-232 port (default) and RS-485 port are supported (option).
- Control and data processing by connecting up to 32 devices to a PC at the same time via RS-485 port.
- Convenient checking with useful graph display.
Multifunction Control System
Description |
No. |
Pattern |
100 |
Repeat time |
999 |
Part repeat time 255 |
255 |
Max. segments/pattern |
100 |
Available max. segments |
2000 |
Programmable process time/segment |
99 hour 59 min. |
* It is possible to set 100 segments per pattern, but the maximum number of segments is not 10,000 (100 patterns x 100 segments) but 2,000.
V-Flow
Exterior Dimensions
Model |
TC3-KE-025 |
TC3-KE-065 |
TC3-KE-100 |
W (mm / inch) |
550 / 21.7 |
600 / 23.6 |
700 / 27.6 |
D (mm / inch) |
880 / 34.6 |
1050 / 41.3 |
1110 / 43.7 |
H (mm / inch) |
915 / 36 |
1060 / 41.7 |
1100 / 43.3 |
A (mm / inch) |
211 / 8.3 |
276 / 10.9 |
276 / 10.9 |
B (mm / inch) |
495 / 19.5 |
580 / 22.8 |
580 / 22.8 |
E (mm / inch) |
170 / 6.7 |
170 / 6.7 |
170 / 6.7 |
F (mm / inch)
|
229 / 9 |
229 / 9 |
229 / 9 |
Outstanding Safety
- Electronic over-temperature protection system (A-OT, advanced over-temperature limiter).
Independent precision temperature sensor and controller for the safer and more accurate over-temperature shutdown.
- Conventional over-temperature protection (B-OT, backup over-temperature limiter).
A backup device for electronic system failure, mechanically preventing over temperature even if an electronic error occurs.
- Door open warning and automatic shut off.
- Over-current and short-circuit protection of the device.
- Each heater has a fuse for more safety.
- Automatic stop when the operating current of the refrigerator is overloaded.
- Automatic stop in case of over temperature of the compressor.
- Auto shut off in case refrigerant pressure (high/low pressure) is abnormal.
Product Name |
Heating & Cooling Chambers
(Tabletop Models) |
Model |
TC-KE |
TC-ME |
Airflow |
Vertical airflow |
Chamber volume (L) |
25, 65, 100 |
Temp. control |
Operating temp. range (℃/℉) |
-35 to 150 / -31 to 302 |
-20 to 150 / -4 to 302 |
Fluctuation at 100℃ (±℃/℉) |
0.5 / 0.9 at 50℃ |
0.4, 0.3 / 2.0, 1.9 |
Variation at 100℃
(±℃/℉) |
1.0 / 1.8 at 50℃ |
2.0, 1.9, 1.8 / 3.6, 3.42, 3.24 |
Control |
Timer |
Wait on/off |
Auto-tuning |
X |
Program function |
X |
Computer interface |
RS-232 port, RS-485 port (optional) |
Safety |
Over temp. limit |
X |
Door open alarm |
X |
Over-current limit |
X |
Auto-run (power failure) |
X |
Optional Accessories
Model |
Cable Port
ø50
|
Cable Port
ø80
|
Wire Shelf |
Perforated Shelf |
Stand
1 Stage
|
Stand
2 Stage
|
Signal Lamp |
Recorder
(Paper)
|
Recorder
(Digital)
|
TC3-KE-025 |
AAA8T612
(included)
|
N/A |
RTD0679 |
AAA80602-6 |
AAA80631 |
AAA80634 |
AAA80550 |
AAA8T504 |
AAA8T506 |
TC3-KE-065 |
AAA8T612
(included)
|
AAA8T611 |
RTD0680 |
AAA80602-7 |
AAA80632 |
AAA80635 |
AAA80550 |
AAA8T504 |
AAA8T506 |
TC3-KE-100 |
AAA8T612
(included)
|
AAA8T611 |
RTD0681 |
AAA80602-8 |
AAA80633 |
N/A |
AAA80550 |
AAA8T504 |
AAA8T506 |